Home › Fox ESS

Fox ESS inverter error codes, the full list

Fox ESS hybrid inverters (H1, AC1, AIO, KH and T-series) show faults as named alarm messages like Grid Lost Fault or BMS Lost on the screen and in the FoxCloud app under Current Alarms. Some series also show a numeric Error N that maps to the same message. Find your fault below, see how urgent it is, and open the step-by-step fix. Start by typing it:

CodeWhat it meansUrgencyFix
Grid Lost FaultNo utility grid detectedSelf-clearsFull fix guide →
Grid Volt FaultGrid voltage out of range (Error 26)Self-clearsFull fix guide →
Grid Freq FaultGrid frequency out of range (Error 27)Self-clearsFull fix guide →
10min Volt Fault10-minute average grid voltage too high (Error 28)Self-clearsFull fix guide →
Bat Volt LowBattery charge/voltage too lowSelf-clearsFull fix guide →
BMS LostLost communication with the battery BMS (Error 14)Check & restartFull fix guide →
Meter Lost FaultLost communication with the meter/CT (Error 242)Check & restartFull fix guide →
Temp FaultInverter over temperatureCheck & restartFull fix guide →
Bat Over TempBattery temperature out of rangeCheck & restartFull fix guide →
PV Volt FaultPV string voltage out of range (Error 17)Check & restartFull fix guide →
Bat Volt FaultBattery voltage out of range (Error 194/198)Check & restartFull fix guide →
SW Bus Vol FaultInternal DC bus voltage out of rangeCheck & restartFull fix guide →
Over Load FaultDemand exceeds the inverter ratingCheck & restartFull fix guide →
Iso FaultLow PV insulation to earth (Error 3)Check & restartFull fix guide →
Res Cur FaultExcess earth-leakage current (RCD)Stop, call a proFull fix guide →
DCI FaultDC injected into the AC output too highStop, call a proFull fix guide →
Arc FaultDC arc detected (AFCI), fire riskStop, call a proFull fix guide →
M1 Close Fault / M2 Close FaultGrid relay stuck or weldedStop, call a proFull fix guide →
PvCon Dir FaultPV polarity reversed (Error 15/16)Stop, call a proFull fix guide →
Inv EEPROM FaultInverter memory corruptedStop, call a proFull fix guide →
Bms HW ProtectBattery BMS hardware protection tripped (Error 211)Stop, call a proFull fix guide →
Communication Fault (Master/Manager)Internal master-manager comms lost (Error 11)Stop, call a proFull fix guide →
Reading the fault on your Fox ESS The alarm shows on the inverter's LCD and in the FoxCloud app and web portal under Current Alarms / History. Note the exact message (and any Error number) and whether it cleared on its own before you start.

How to read the urgency rating

Self-clears usually a passing grid or weather event; the inverter reconnects itself.
Check & restart do a few safe checks and a proper power cycle.
Stop, call a pro a safety or hardware fault; don't keep resetting it.