Sunsynk F35: No AC Grid / No Utility
F35 is the Sunsynk telling you it can't see the utility grid. On a grid-tied setup it then stops exporting and waits. Most of the time this is not a fault at all: it is a power cut or a breaker that tripped between the inverter and the grid. When mains power comes back, F35 normally clears by itself.
Grid, wiring, or inverter?
F35 sits firmly on the grid side. Most likely first:
- A utility outage. Check whether the rest of the house is also dark. If the whole place is out, it is load-shedding or a cut, just wait.
- A tripped breaker or open isolator on the line between the inverter and the meter.
- A loose AC connection at the inverter or distribution board.
- Grid voltage or frequency out of limits, where the supply is too unstable for the inverter to connect.
How to check it safely
- Is the power out? Look at the rest of the house or ask a neighbour. If the grid is down, F35 will clear when power returns. Nothing to fix.
- Check the AC breaker and isolator between the inverter and the grid. Make sure it is on, and reset it if it tripped.
- Confirm the main supply by checking the main breaker and meter have power.
- Allow the reconnection delay. After power returns, the Sunsynk waits a short, standards-required time before it comes back online. This pause is normal.
- Grid present but F35 stays? Do a safe power cycle (AC off, DC isolator off, wait five minutes, restart). If it still won't connect, the AC connection or grid-detection may need a look.
Quick decision flowchart
Related Sunsynk codes
FAQ
F35 shows but my house has power.
The inverter sees the grid only through its own AC connection. If a breaker or isolator on that line is off, or a connection is loose, it reads "no grid" even though the house is powered. Check that breaker first.
Will my system run on battery during F35?
On a hybrid Sunsynk with backup, the battery keeps your backup loads going during a real outage. F35 simply reflects that the grid is absent; the inverter reconnects when mains returns.
How long until F35 clears after power is back?
Grid-tied inverters wait a short, standards-required reconnection delay (often a few minutes) once the grid is stable. A brief wait is normal.